Description
Avery SF100 SPECIALTY FILMS Holographic KALEIDOSCOPE
Avery GraphicsTM Holographic films are light diffracting metallized, UV-stabilized, rigid vinyl films designed for indoor promotional use in signs, decals, and POP displays and short-term outdoor signage.
Avery® SF 100 Holographic Series
Permanent – Kraft
(formerly: A0 Holographic Series )
Revision: 1 Dated: 6/08/2009
Product Data Sheet
Page 1 of 3
Uses:
Avery GraphicsTM Holographic films are light
diffracting metallized, UV-stabilized, rigid
vinyl films designed for indoor promotional
use in signs, decals, and POP displays and
short-term outdoor signage.
Face: 2.4 mil (61 microns) rigid
metalized PVC
Adhesive: Clear Permanent
Acrylic
Liner: 78# Kraft
Durability: 6 months
Application
Surfaces:
Flat
Features:
Dimensionally stable liner for easy converting
Excellent conversion on CAD plotters
Easy cutting & weeding
Excellent dimensional stability
Excellent UV, temperature, humidity, and salt-spray resistance
Short Term Promotional Applications
Conversion:
Thermal Die-Cutting
Flat Bed Sign-Cut
Drum Roller Sign-Cut
Steel Rule Die-Cutting
Thermal Transfer
Screen Printing
Cold Overlaminating
Water based inkjet
Solvent based inkjet
Mild/Eco Solvent inkjet
UV inkjet
Common Applications:
Emblems Promotions Specialty Pieces
Avery® SF 100 Holographic Series
Permanent – Kraft
(formerly: A0 Holographic Series )
Revision: 1 Dated: 6/08/2009
Product Data Sheet
Page 2 of 3
Graphics & Reflective Products Division AnswerLine: 800-231-4654
250 Chester Street www.averygraphics.com
Painesville, OH 44077
Physical Characteristics:
Property Value
Caliper, face 2.4 mil (61 microns)
Caliper, adhesive 1.0mil (25 µm)
Dimensional
stability
<0.025(0.7mm)
Tensile at Yield NA
Elongation NA
Gloss Gloss
Adhesion: Acrylic 24 hr.
1 week
4.1 lbs/in (718 N/m)
4.4 lbs/in (770 N/m)
Flammability Self Extinguishing
Shelf-Life 1 year
Durability Vertical
Exposure
Up to 6 months
Min. Application
Temperature
50° F (10° C)
Service
Temperature
-40° – 176°F (-40° – 80° C)
(Reasonable range of
temperatures which would
be expected under normal
environmental conditions).
Chemical
resistance
Resistant to most mild
acids, alkalis, and salt
solutions.
Important:
Information on physical and chemical characteristics
are based on tests believed to be reliable. The values
are intended only as a source of information. This
information is given without guaranty and do not
constitute a warranty. The purchaser should
independently determine, prior to use, the suitability of
any material for their specific purpose. (Data
represents average values where applicable, and is
not intended for specification purposes)
Warranty:
All statements, technical information and
recommendations about Avery Dennison
products are based upon tests believed to be
reliable but do not constitute a guarantee or
warranty. All Avery Dennison products are sold
with the understanding that Purchaser has
independently determined the suitability of such
products for its purposes. Avery Dennison
products are warranted to be free from defects in
material and workmanship for either one year (or
the period stated on the specific product
information literature in effect at time of delivery, if
longer) from date of shipment if said product is
properly stored and applied. It is expressly agreed
and understood that Avery Dennison’s sole
obligation and Purchaser’s exclusive remedy
under this warranty, under any other warranty,
express or implied, or otherwise, shall be limited
to repair or replacement of defective product
without charge at Avery Dennison’s plant or at the
location of product (at Avery Dennison’s election),
or in the event replacement or repairs is not
commercially practical, to Avery Dennison’s
issuing Purchaser a credit reasonable in light of
the defect in the product.
Avery Dennison’s liability for defective products
shall not exceed the purchase price paid
therefore by Purchaser and in no event shall
Avery Dennison be responsible for any incidental
or consequential damages whether foreseeable
or not, caused by defects in such product,
whether such damage occurs or is discovered
before or after replacement or credit, and whether
or not such damage is caused by Avery
Dennison’s negligence.
NO EXPRESS WARRANTIES AND NO IMPLIED
WARRANTIES, WHETHER OF
MERCHANTABILITY OR FITNESS FOR ANY
PARTICULAR USE, OR OTHERWISE (EXCEPT
AS TO TITLE), OTHER THAN THOSE
EXPRESSLY SET FORTH ABOVE WHICH ARE
MADE EXPRESSLY IN LIEU OF ALL OTHER
WARRANTIES, SHALL APPLY TO PRODUCTS
SOLD BY AVERY DENNISON. AVERY
DENNISON SPECIFICALLY DISCLAIMS AND
EXCLUDES ALL OTHER SUCH WARRANTIES.
NO WAIVER, ALTERATION, ADDITION OR
MODIFICATION OF THE FOREGOING
CONDITIONS SHALL BE VALID UNLESS MADE
IN WRITING AND MANUALLY SIGNED BY AN
OFFICER OF AVERY DENNISON.
Avery® SF 100 Holographic Series
Permanent – Kraft
(formerly: A0 Holographic Series )
Revision: 1 Dated: 6/08/2009
Product Data Sheet
Page 3 of 3
Graphics & Reflective Products Division AnswerLine: 800-231-4654
250 Chester Street www.averygraphics.com
Painesville, OH 44077
Colors: Cross Reference
SPECIALTY SERIES –
78#
AVERY 100 SPECIALTY
FILMS PERMANENT KRAFT
SPECIALTY SERIES –
78#
AVERY 100 SPECIALTY
FILMS PERMANENT KRAFT
A0839-S Confetti SF 100-839-S Confetti A0846-S Kaleidoscope SF 100-847-S Kaleidoscope
COMMENTS:
NOTE: Some color fade may occur in severe environmental areas. Reference IB 1.30 for durability guidelines.
Dimensional stability:
Is measured on a 6 x 6 (150 x 150 mm) aluminum panel to which a specimen has been applied; 72 hours after
application the panel is scored in a cross pattern, exposed for 48 hours to 150°F (65°C), after which the shrinkage is
measured.
Adhesion:
(FTM-1, FINAT) is measured by peeling a specimen at a 180° angle from a stainless steel panel, 24 hour s after the
specimen has been applied under standardized conditions. Initial adhesion is measured 15 minutes after application of
the specimen.
Flammability:
A specimen applied to aluminum is subjected to the flame of a gas burner for 15 seconds. The film should stop burning
within 15 seconds after removal from the flame.
Temperature range:
A specimen applied to stainless steel is exposed at high and low temperatures and brought back to room temperature. 1
hour after exposure the specimen is examined for any deterioration. Note: Prolonged exposure to high and low
temperatures in the presence of chemicals such as solvents, acids, dyes, etc. may eventually cause deterioration.
Chemical Resistance:
All chemical tests are conducted with test panels to which a specimen has been applied. 72 hours after application the
panels are immersed in the test fluid for the given test period. 1 hour after removing the panel from the fluid, the specimen
is examined for any deterioration.